ИБП SG Series 10-600 кВА, промышленные ибп, ибп промышленный, Промышленные ИБП, промышленный ибп, промышленные источники бесперебойного питания, ибп для сервера, ибп для серверов, источник бесперебойного питания промышленный, промышленный источник

UPS GT Series 6000-10000 ВА

GT Series UPS manufactured by GE Digital Energy are devices of VFI Class (Voltage & Frequency Independent – voltage and output frequency do not depend on input) produced on the basis of double conversion process (on-line) and purposed for protection of your equipment against any interferences in the network including complete voltage failure. 

 

  •  [ 2008 Kb ] 
UPS GT 6000, GT 10 000, ups, power supplies, apc, UPS, UPS, uninterruptible power supply, uninterruptible power supplies, ups ups, ups, uninterruptible power supplies UPS, ups apc, power supply ups, uninterruptible power supplies ups, ups power UPS besper

The UPS are installed vertically or may be installed in 19” cabinet so the UPS installation is adapted in course of the network development. The mounting accessories are included into the supply.

Differential peculiarity of the GT Series UPS is parallel work of up to 3 UPSes (N+2). All necessary components: a parallel operation card, parallel operation wire is included into delivery set of every UPS and allow integrating of up to 3 UPSes.

Possibility of fast, profound battery tests providing reliability and maximal service life of the batteries. For connection with a computer, the UPS is equipped with the RS232 port operating even if the UPS is in stand-by mode. Interface SNMP board for network monitoring is an option and guarantees possibility of remote control.

ups, упс, бесперебойник, источники безперебойного питания, купить ибп, ибп для компьютера, ибп цена, источник бесперебойного питания купить, источники бесперебойного питания для компьютеров, источники бесперебойного питания цена, бесперебойник купить, бесперебойник цена, ибп цены, ибп on-line, источник бесперебойного питания smart, источники бесперебойного питания цены, ибп украина, источники бесперебойного питания on line, ибп on line купить


Features and Benefits
  • Parallel switching is possible: N+2
  • Double conversion technology (on-line) solves the problems of providing reliability of power supply
  • Both Floor-standing and rack-mount UPS enclosure design. All mounting elements are in delivery set.
  • Simple procedure of battery substitute that does not affect load power
  • Simple procedure of connection battery units to increase the autonomous operation time
  • Remote monitoring and control if the UPS is installed in the places of restricted access
  • May be used as a frequency convertor 50/60 Hz and vice versa.
  • Wide range of input voltage: 85-276 V (176-276 V at 100% load)
  • Height of energy supply module 3U, height of battery unit 3U 
Fields of application
  • Servers
  •  Security systems
  • Telecommunication equipment
  • Satellite systems
  • Local computing networks
  • Manufacturing equipment
  • Internet-servers
  • Communications centers
  • IP-telephony
GT 6000
Nominal output power:  6000VA / 4200W
Enclosure design:  tower/ rack-mount
Range of input voltage at 70% load:  84 - 276 V
Range of input frequency (Hz):  40 - 70
Output power factor:  > 0,97
Input voltage (V):  220 / 230 / 240 +/- 2% (selectable)
Output frequency (Hz):  50 / 60 (automatic selection)
Cross factor:  3 : 1
Parallel operation:  up to 3 devices
Autonomy time at 75 % -load (min):  17
UPS power module (H х W х D, mm):  130 х 410 х 660 (3 units)
Battery cabinet (H х W х D, mm):  130 х 410 х 660 (3 units)
Weight of UPS power module (kg):  24,5
Weight of UPS battery cabinet (kg):  67
Additional battery units:  +
SNMP:  +
Price, ?:  -
GT 10000
Nominal output power:  10000VA / 7000W
Enclosure design:  tower/ rack-mount
Range of input voltage at 70% load:  84 - 276 V
Range of input frequency (Hz):  40 - 70
Output power factor:  > 0,97
Input voltage (V):  220 / 230 / 240 +/- 2% (selectable)
Output frequency (Hz):  50 / 60 (automatic selection)
Cross factor:  3 : 1
Parallel operation:  up to 3 devices
Autonomy time at 75 % -load (min):  9
UPS power module (H х W х D, mm):  130 х 410 х 660 (3 units)
Battery cabinet (H х W х D, mm):  130 х 410 х 660 (3 units)
Weight of UPS power module (kg):  24,5
Weight of UPS battery cabinet (kg):  67
Additional battery units:  +
SNMP:  +
Price, ?:  -
Model
GT 6000
Nominal output power:  6000VA / 4200W
Enclosure design:  tower/ rack-mount
Range of input voltage at 70% load:  84 - 276 V
Range of input frequency (Hz):  40 - 70
Output power factor:  > 0,97
Input voltage (V):  220 / 230 / 240 +/- 2% (selectable)
Output frequency (Hz):  50 / 60 (automatic selection)
Cross factor:  3 : 1
Parallel operation:  up to 3 devices
Autonomy time at 75 % -load (min):  17
UPS power module (H х W х D, mm):  130 х 410 х 660 (3 units)
Battery cabinet (H х W х D, mm):  130 х 410 х 660 (3 units)
Weight of UPS power module (kg):  24,5
Weight of UPS battery cabinet (kg):  67
Additional battery units:  +
SNMP:  +
Price, ?:  -
Specifications

Operating Characteristics

  • Operating temperature : from 0 up to 40° C
  • Relative humidity : 90% without condensation
  • Noise level : < 45  dB(A), depends on the load

 

Standards and Regulations

  • Safety : EN 62040-1
  • EMC : EN 62040-2 (2006)
  • Enclosure design : IP20