LP 5 - 11 / LP 5 - 31T
UPS: |
 |
Single-phase UPS |
Output power at cos? = 0.6-0.8: |
 |
5kVA |
Output power (kVA): |
 |
4kW |
Accumulator batteries (V/Аh): |
 |
240/7 |
Charging rate (А): |
 |
2,0 |
Additional charger 8А: |
 |
+ |
Charging period: |
 |
1.5-3 hours till 80% of capacity |
Output power factor (cos?): |
 |
0,99 |
Standard autonomy time at 50/100% load (min): |
 |
23/10 |
Output isolation transformer: |
 |
Standard equipment list |
Dimensions (H х W х D): |
 |
537 х 313 х 590 mm |
Noise level (dB(A)): |
 |
40-50 (EN27779) in dependence on load and temperature |
Weight (kg): |
 |
110 (LP-11) / 180 (LP-31T) |
Protection class: |
 |
IP20 |
Input voltage range (V): |
 |
172-285 (LP-11) / 340-460 (LP-31T) |
Input frequency range (Hz): |
 |
40-70 |
Input voltage (V): |
 |
220/230/240 (selected by user) |
Output frequency (Hz): |
 |
50/60 Hz (± 0,1%) |
Cross-factor: |
 |
5:1 |
Parallel operation: |
 |
up to 4 devices |
Distortion of output voltage (THD) at linear load: |
 |
<1% |
Distortion of output voltage (THD) at non-linear load: |
 |
<10% max. at cross-factor 2,5:1 |
Output voltage constancy at static load: |
 |
±1% |
Output voltage constancy at dynamic load (alternation – 0 -100-0%): |
 |
< ±2% (recovery time < 10ms) |
Overload capability of inverter: |
 |
110% - 20 min. 130% - 3.5 min. 150% - 2 min. |
Environment operating temperatu: |
 |
UPS: - 10 - + 40 ? C Battery: 15-25 ? C |
Humidity: |
 |
95% without condensate |
Safety standards: |
 |
EN 50091-1-1; EN/IEC 60950 |
EMC standard: |
 |
EN 50091-2 |
Standard interface: |
 |
RS232, dry-type contacts |
Advances batteries control: |
 |
+ |
Options: |
 |
RPA, SNMP-card, additional battery enclosures | |
LP 6 - 11 / LP 6 - 31T
UPS: |
 |
Single-phase power supply |
Output power at cos? = 0.6-0.8: |
 |
6kVA |
Output power (kVA): |
 |
4,8kW |
Accumulator batteries (V/Аh): |
 |
240/7 |
Charging rate (А): |
 |
2,0 |
Additional charger 8А: |
 |
+ |
Charging period: |
 |
1.5-3 hours till 80% of capacity |
Output power factor (cos?): |
 |
0,99 |
Standard autonomy time at 50/100% load (min): |
 |
20/8 |
Output isolation transformer: |
 |
Standard equipment list |
Dimensions (H х W х D): |
 |
537 х 313 х 590 mm |
Noise level (dB(A)): |
 |
40-50 (EN27779) in dependence on load and temperature |
Weight (kg): |
 |
115 (LP-11) / 185 (LP-31T) |
Protection class: |
 |
IP20 |
Input voltage range (V): |
 |
172-285 (LP-11) / 340-460 (LP-31T) |
Input frequency range (Hz): |
 |
40-70 |
Input voltage (V): |
 |
220/230/240 (selected by user) |
Output frequency (Hz): |
 |
50/60 Hz (± 0,1%) |
Cross-factor: |
 |
5:1 |
Parallel operation: |
 |
up to 4 devices |
Distortion of output voltage (THD) at linear load: |
 |
<1% |
Distortion of output voltage (THD) at non-linear load: |
 |
<10% max. at cross-factor 2,5:1 |
Output voltage constancy at static load: |
 |
±1% |
Output voltage constancy at dynamic load (alternation – 0 -100-0%): |
 |
< ±2% (recovery time < 10ms) |
Overload capability of inverter: |
 |
110% - 20 min. 130% - 3.5 min. 150% - 2 min. |
Environment operating temperatu: |
 |
UPS: - 10 - + 40 ? C Battery: 15-25 ? C |
Humidity: |
 |
95% without condensate |
Safety standards: |
 |
EN 50091-1-1; EN/IEC 60950 |
EMC standard: |
 |
EN 50091-2 |
Standard interface: |
 |
RS232, dry-type contacts |
Advances batteries control: |
 |
+ |
Options: |
 |
RPA, SNMP-card, additional battery enclosures | |
LP 8 - 11 / LP 8 - 31T
UPS: |
 |
UPS Single-phase |
Output power at cos? = 0.6-0.8: |
 |
8kVA |
Output power (kVA): |
 |
6,4kW |
Accumulator batteries (V/Аh): |
 |
240/12 |
Charging rate (А): |
 |
3 |
Additional charger 8А: |
 |
+ |
Charging period: |
 |
1.5-3 hours till 80% of capacity |
Output power factor (cos?): |
 |
0,99 |
Standard autonomy time at 50/100% load (min): |
 |
26/11 |
Output isolation transformer: |
 |
Standard equipment list |
Dimensions (H х W х D): |
 |
680 х 313 х 720 mm |
Noise level (dB(A)): |
 |
40-50 (EN27779) in dependence on load and temperature |
Weight (kg): |
 |
165 (LP-11) / 270 (LP-31T) |
Protection class: |
 |
IP20 |
Input voltage range (V): |
 |
172-285 (LP-11) / 340-460 (LP-31T) |
Input frequency range (Hz): |
 |
40-70 |
Input voltage (V): |
 |
220/230/240 (selected by user) |
Output frequency (Hz): |
 |
50/60 Hz (± 0,1%) |
Cross-factor: |
 |
5:1 |
Parallel operation: |
 |
up to 4 devices |
Distortion of output voltage (THD) at linear load: |
 |
<1% |
Distortion of output voltage (THD) at non-linear load: |
 |
<10% max. at cross-factor 2,5:1 |
Output voltage constancy at static load: |
 |
±1% |
Output voltage constancy at dynamic load (alternation – 0 -100-0%): |
 |
< ±2% (recovery time < 10ms) |
Overload capability of inverter: |
 |
110% - 20 min. 130% - 3.5 min. 150% - 2 min. |
Environment operating temperatu: |
 |
UPS: - 10 - + 40 ? C Battery: 15-25 ? C |
Humidity: |
 |
95% without condensate |
Safety standards: |
 |
EN 50091-1-1; EN/IEC 60950 |
EMC standard: |
 |
EN 50091-2 |
Standard interface: |
 |
RS232, dry-type contacts |
Advances batteries control: |
 |
+ |
Options: |
 |
RPA, SNMP-card, additional battery enclosures | |
LP 10-11 / LP 10-31T
UPS: |
 |
Single-phase UPS |
Output power at cos? = 0.6-0.8: |
 |
10kVA |
Output power (kVA): |
 |
8kW |
Accumulator batteries (V/Аh): |
 |
240/12 |
Charging rate (А): |
 |
3 |
Additional charger 8А: |
 |
+ |
Charging period: |
 |
1.5-3 hours till 80% of capacity |
Output power factor (cos?): |
 |
0,99 |
Standard autonomy time at 50/100% load (min): |
 |
20/8 |
Output isolation transformer: |
 |
Standard equipment list |
Dimensions (H х W х D): |
 |
680 х 313 х 720 mm |
Noise level (dB(A)): |
 |
40-50 (EN27779) in dependence on load and temperature |
Weight (kg): |
 |
170 (LP-11) / 275 (LP-31T) |
Protection class: |
 |
IP20 |
Input voltage range (V): |
 |
172-285 (LP-11) / 340-460 (LP-31T) |
Input frequency range (Hz): |
 |
40-70 |
Input voltage (V): |
 |
220/230/240 (selected by user) |
Output frequency (Hz): |
 |
50/60 Hz (± 0,1%) |
Cross-factor: |
 |
5:1 |
Parallel operation: |
 |
up to 4 devices |
Distortion of output voltage (THD) at linear load: |
 |
<1% |
Distortion of output voltage (THD) at non-linear load: |
 |
<10% max. at cross-factor 2,5:1 |
Output voltage constancy at static load: |
 |
±1% |
Output voltage constancy at dynamic load (alternation – 0 -100-0%): |
 |
< ±2% (recovery time < 10ms) |
Overload capability of inverter: |
 |
110% - 20 min. 130% - 3.5 min. 150% - 2 min. |
Environment operating temperatu: |
 |
UPS: - 10 - + 40 ? C Battery: 15-25 ? C |
Humidity: |
 |
95% without condensate |
Safety standards: |
 |
EN 50091-1-1; EN/IEC 60950 |
EMC standard: |
 |
EN 50091-2 |
Standard interface: |
 |
RS232, dry-type contacts |
Advances batteries control: |
 |
+ |
Options: |
 |
RPA, SNMP-card, additional battery enclosures | |
LP 8 - 31
UPS: |
 |
Single-phase power supply |
Output power at cos? = 0.6-0.8: |
 |
8kVA |
Output power (kVA): |
 |
6,4kW |
Accumulator batteries (V/Аh): |
 |
2 х 240/7 |
Charging rate (А): |
 |
2 х 2,1 |
Additional charger 8А: |
 |
+ |
Charging period: |
 |
1.5-3 hours till 80% of capacity |
Output power factor (cos?): |
 |
0,95 |
Standard autonomy time at 50/100% load (min): |
 |
35/14 |
Output isolation transformer: |
 |
|
Dimensions (H х W х D): |
 |
1190 х 410 х 890 mm |
Noise level (dB(A)): |
 |
40-50 (EN27779) in dependence on load and temperature |
Weight (kg): |
 |
250 (7 Ah batareї.) - 355 (batareї 14 Ah.) |
Protection class: |
 |
IP20 |
Input voltage range (V): |
 |
3 x 300...470 + N |
Input frequency range (Hz): |
 |
46 - 65 |
Input voltage (V): |
 |
220/230/240 (selected by user) |
Output frequency (Hz): |
 |
50/60 Hz (± 0,1%) |
Cross-factor: |
 |
5:1 |
Parallel operation: |
 |
- |
Distortion of output voltage (THD) at linear load: |
 |
<1% |
Distortion of output voltage (THD) at non-linear load: |
 |
<5% |
Output voltage constancy at static load: |
 |
±1% |
Output voltage constancy at dynamic load (alternation – 0 -100-0%): |
 |
< ±2% (recovery time < 10ms) |
Overload capability of inverter: |
 |
120% - 10 sec., 150% - 2 sec. |
Environment operating temperatu: |
 |
UPS: - 10 - + 40 ? C Battery: 15-25 ? C |
Humidity: |
 |
95% without condensate |
Safety standards: |
 |
EN 50091-1-1; EN/IEC 60950 |
EMC standard: |
 |
EN 50091-2 |
Standard interface: |
 |
RS232, dry-type contacts |
Advances batteries control: |
 |
+ |
Options: |
 |
RPA, SNMP-card, additional battery enclosures | |
LP 10-31
UPS: |
 |
UPS Single-phase |
Output power at cos? = 0.6-0.8: |
 |
10kVA |
Output power (kVA): |
 |
8kW |
Accumulator batteries (V/Аh): |
 |
2 х 240/7 |
Charging rate (А): |
 |
2 х 2,1 |
Additional charger 8А: |
 |
+ |
Charging period: |
 |
1.5-3 hours till 80% of capacity |
Output power factor (cos?): |
 |
0,95 |
Standard autonomy time at 50/100% load (min): |
 |
34/10 |
Output isolation transformer: |
 |
|
Dimensions (H х W х D): |
 |
1190 х 410 х 890 mm |
Noise level (dB(A)): |
 |
40-50 (EN27779) in dependence on load and temperature |
Weight (kg): |
 |
250 (7 Ah batareї.) - 355 (batareї 14 Ah.) |
Protection class: |
 |
IP20 |
Input voltage range (V): |
 |
3 x 300...470 + N |
Input frequency range (Hz): |
 |
46 - 65 |
Input voltage (V): |
 |
220/230/240 (selected by user) |
Output frequency (Hz): |
 |
50/60 Hz (± 0,1%) |
Cross-factor: |
 |
5:1 |
Parallel operation: |
 |
- |
Distortion of output voltage (THD) at linear load: |
 |
<1% |
Distortion of output voltage (THD) at non-linear load: |
 |
<5% |
Output voltage constancy at static load: |
 |
±1% |
Output voltage constancy at dynamic load (alternation – 0 -100-0%): |
 |
< ±2% (recovery time < 10ms) |
Overload capability of inverter: |
 |
120% - 10 sec., 150% - 2 sec. |
Environment operating temperatu: |
 |
UPS: - 10 - + 40 ? C Battery: 15-25 ? C |
Humidity: |
 |
95% without condensate |
Safety standards: |
 |
EN 50091-1-1; EN/IEC 60950 |
EMC standard: |
 |
EN 50091-2 |
Standard interface: |
 |
RS232, dry-type contacts |
Advances batteries control: |
 |
+ |
Options: |
 |
RPA, SNMP-card, additional battery enclosures | |
LP 15-31
UPS: |
 |
Single-phase UPS |
Output power at cos? = 0.6-0.8: |
 |
15kVA |
Output power (kVA): |
 |
12kW |
Accumulator batteries (V/Аh): |
 |
2 х 240/14 |
Charging rate (А): |
 |
2 х 4,2 |
Additional charger 8А: |
 |
+ |
Charging period: |
 |
1.5-3 hours till 80% of capacity |
Output power factor (cos?): |
 |
0,95 |
Standard autonomy time at 50/100% load (min): |
 |
30/13 |
Output isolation transformer: |
 |
|
Dimensions (H х W х D): |
 |
1190 х 410 х 890 mm |
Noise level (dB(A)): |
 |
40-50 (EN27779) in dependence on load and temperature |
Weight (kg): |
 |
365 |
Protection class: |
 |
IP20 |
Input voltage range (V): |
 |
3 x 300...470 + N |
Input frequency range (Hz): |
 |
46 - 65 |
Input voltage (V): |
 |
220/230/240 (selected by user) |
Output frequency (Hz): |
 |
50/60 Hz (± 0,1%) |
Cross-factor: |
 |
5:1 |
Parallel operation: |
 |
- |
Distortion of output voltage (THD) at linear load: |
 |
<1% |
Distortion of output voltage (THD) at non-linear load: |
 |
<5% |
Output voltage constancy at static load: |
 |
±1% |
Output voltage constancy at dynamic load (alternation – 0 -100-0%): |
 |
< ±2% (recovery time < 10ms) |
Overload capability of inverter: |
 |
120% - 10 sec., 150% - 2 sec. |
Environment operating temperatu: |
 |
UPS: - 10 - + 40 ? C Battery: 15-25 ? C |
Humidity: |
 |
95% without condensate |
Safety standards: |
 |
EN 50091-1-1; EN/IEC 60950 |
EMC standard: |
 |
EN 50091-2 |
Standard interface: |
 |
RS232, dry-type contacts |
Advances batteries control: |
 |
+ |
Options: |
 |
RPA, SNMP-card, additional battery enclosures | |
LP 20-31
UPS: |
 |
Single-phase power supply |
Output power at cos? = 0.6-0.8: |
 |
20kVA |
Output power (kVA): |
 |
16kW |
Accumulator batteries (V/Аh): |
 |
2 х 240/14 |
Charging rate (А): |
 |
2 х 4,2 |
Additional charger 8А: |
 |
+ |
Charging period: |
 |
1.5-3 hours till 80% of capacity |
Output power factor (cos?): |
 |
0,95 |
Standard autonomy time at 50/100% load (min): |
 |
24/10 |
Output isolation transformer: |
 |
|
Dimensions (H х W х D): |
 |
1190 х 410 х 890 mm |
Noise level (dB(A)): |
 |
40-50 (EN27779) in dependence on load and temperature |
Weight (kg): |
 |
365 |
Protection class: |
 |
IP20 |
Input voltage range (V): |
 |
3 x 300...470 + N |
Input frequency range (Hz): |
 |
46 - 65 |
Input voltage (V): |
 |
220/230/240 (selected by user) |
Output frequency (Hz): |
 |
50/60 Hz (± 0,1%) |
Cross-factor: |
 |
5:1 |
Parallel operation: |
 |
- |
Distortion of output voltage (THD) at linear load: |
 |
<1% |
Distortion of output voltage (THD) at non-linear load: |
 |
<5% |
Output voltage constancy at static load: |
 |
±1% |
Output voltage constancy at dynamic load (alternation – 0 -100-0%): |
 |
< ±2% (recovery time < 10ms) |
Overload capability of inverter: |
 |
120% - 10 sec., 150% - 2 sec. |
Environment operating temperatu: |
 |
UPS: - 10 - + 40 ? C Battery: 15-25 ? C |
Humidity: |
 |
95% without condensate |
Safety standards: |
 |
EN 50091-1-1; EN/IEC 60950 |
EMC standard: |
 |
EN 50091-2 |
Standard interface: |
 |
RS232, dry-type contacts |
Advances batteries control: |
 |
+ |
Options: |
 |
RPA, SNMP-card, additional battery enclosures | |